Bug  Description
4181 First dispatch timestep on reach is incorrect when stream gage is present.
4951 Optimization table interpolation error message
5476 Model report preview not working for some RPL sets. / Enum rwSetting enhancement.
5491 Interpolation tolerance for 3-D interpolation too tight
5511 Plot Date/Time on Y-axis
5514 Diagnotics message MSG_SLOT_TOO_HIGH_LOW used incorrectly
5515 Slots stay visible when changing power methods
5523 Increasing precision in ruleset and editing always reverts to 8 digits of precision.
5532 Optimization Solution Analysis Tool (POSAT) window doesn't raise if already opened.
5534 Huge delay posting myriad overdetermination error messages on run abort
5537 Warning messages in optimization have bad context information
5545 When object dispatch is disabled, crosshatch is not always shown in the SCT
5546 Don't shrink tables on load if there are row labels
5547 RPL function breakpoints sometimes ignored within optimization goals
5548 DSS dataset file selector unnecessarily asked about replacing the DSS file for an input DMI.
5550 The Script Dashboard's execute run progress bars are not working
5551 Crash when a script which is executing a run is stopped
5552 Negative Outflow on the Distribution Canal – Available water is now constrained to be non-negative.
5553 Apparent tolerance problem with Inline Power Plant
5555 Pan Ice Switch, K Factor periodic slots not setting series slots, causing an abort.
5556 Problem with a background image in a model package
5557 3D interpolation
5558 Riverware freezes after using Execute Run script action
5559 edit date/time broken for some Script Dashboard actions.
5560 SCT columns in hidden sheets (subtabs) resize after a run
5562 Run numbers with Excel DMIs in MRM
5564 RPL function SolveTurbineReleaseGivenEnergyInflow not returning the correct bool values.
5566 Water Users on Agg Diversion Sites were not dispatching WQ methods.
5567 Problem with the HydropowerRelease function with Phase Balancing flood control
5569 Not post-processing scenarios in RiverSMART
5573 Crash caused by user-defined parameters in DMI control file
5575
5581
Right clicking in an SCT series cell in certain circumstances could cause a crash.
5576 Opt hard constraints after an empty Repeated Maximin do not get added
5577 Tabular Series Slot Report didn't support Monthly Timestep in Daily Model.
5578 Data Object Table Slots: several available column operations not being shown (e.g. Insert Column).
5579 DMI connection to DSS refused
5580 SCT 'Init Rules' series timestep cell Tooltip and Context Menu Problems.
5582 Huge delay operating Model Run Analysis dialog's Rules Effects panel with large Ruleset.
5583 Object Attribute Manager dialog: Missing button icons.
5584 Open Account Dialog and SCTs opened from an SCT file are not initially scrolled to the global time.
5587 Open Slot dialog: undesirable rescroll to selected cells after display change operations.
5590 Accounting Method categories were not displayed correctly on Control Points, Diversion Objects, Pipe Junctions, and Inline Pumps.
5591 On the Open Object dialog, the input I flag icon was not updating when the timestep changed.
5594 The SCT could jump to a different tab when removing a slot.
5596 RiverSMART crashes when selecting "Post-process" scenarios
5600 The passthrough account was solving incorrectly when Gain Loss was specified.
5601 POSAT misreports some values when a model is loaded
5605 Open Slot Dialog: more careful presentation of Cut/Delete Rows operations.
5606 DSS DMI problems importing monthly data.
5607 RPL predefined function toCelsius is spelled incorrectly
5609 Open Account dialog not updated when creating supplies on the workspace.
5611 Tool tip on Input accounting slots is incorrect.
5612 Two runs are fine, third run produces an error
5613 Table slot row label displays cut off underscores
5614 Annual Aggregation time series slots not correctly summing monthly flows in units of AF/month
5616 Power table extrapolation error
5622 The RPL unit parser misinterprets some units
5623 Running CRSS and hitting an error gives many new assertion messages.
5626 Probability and Logarithmic Plot Axes had been reverting to Linear Scale.
5628 Problem with the Peak Power Equation with Off Peak Spill method.
5629 Object clusters were interfering with Computational Subbasin flood control methods.
5630 Import Paste: "Limit paste operation" default setting change
5632 Initialization issue when not using methods to initialize for routing
5633 Import (Resize) on table slots does not change the number of columns.
5634 A model with > 200,000 timesteps could crash during load.
5636 Sloped reservoirs in No-opt subbasin are still doing beginning of run behavior.
5637 Output DMI writes bad end date when series slot is empty
5638 RiverWare can't plot a timeseries beyond the year 3000.
5639 Core dump on clear workspace or RiverWare exit.
5641 In Model Report or Script configurations, selecting the first item in a pull-down setting menu did not always work.
5642 Closing all dialogs opens (as minimized) RPL Set dialogs.
5643 Unable to load a model with extremely long time range
5644 Specifying Plant Power Limit in the Plant Power Equation method could lead to a crash.
5645 RPL analysis does not add columns for ascending/descending tabs.
5646 DIT slot name Request should be Requested on data tabs
5647 RiverWare crashes when hitting an over determination error due to link
5648 RPL OptValue predefined function sometimes incorrectly aborts run when debugger is enabled
5655 Expression slot diagnostics with no context which turn on when PRINT statements are enabled
5657 Default workspace location when loading a model is not correct.
5660 Negative Diversion due to Soil Moisture.
5661 Instabilities encountered while debugging a TVA optimization model.
5662 Abort run notification dialog presents bogus timestep context for optimization runs
5663 Script not able change a method to None. [fixed with 5641].
5665 Slot Copy AggObj Element slots, Paste to DataObj: Slot name problem
5667 Assertion Failure in script editor when selecting enumerated setting.
5669 DSS DMI not writing data type or units to the DSS file
5670 Water User Soil Moisture Methods run in 6.6.6 but not in 6.7
5671 Teacup Legend could not be added to Output Canvas
5673 Data Object default slot naming problem, pasting slots.
5680 Equal Priority water rights algorithm infinite loop.
 
Unfiled Bug [Nov 2014] Error with Trace DMI in MRM when not specifying a control file template
Unfiled Bug [Dec 2014] Script Dashboard, some values were displayed in standard units instead of user units
Unfiled Bug [Apr 2015] RCL command names mismatched between RiverSMART and RiverWare
Unfiled Bug [Apr 2015] More robust implementation of temporary file creation when line endings are converted for an output control file-executable DMI
Unfiled Bug [May 2015] User gets Trace 1 data for all traces when executing a Trace Directory DMI from RiverSMART

Bugs Closed without code change being made.

Bug Description Reason
4956 Cannot build DSS server No longer relevant
5362 RW Crashing during MRM Runs No longer relevant
5525 Program quits unexpectedly No longer relevant
5533 Program crashes No longer relevant
5568 RiverWare icon reverts to default color Intended behavior
5574 Reopen model menu isn't working Can't reproduce
5585 Flow in months with less than 31 days not being set correctly to outflow slots. Intended behavior
5668 URGWOM Account Model Run not working in RW6.7 Intended behavior

---